MODSYS16 PCA INV
COMBINATION SYSTEMS
As cable maintenance becomes ever more challenging, test engineers require more sophisticated methods to easily and accurately pinpoint the position of cable faults.
The MODSYS16-PCA-INV fault location system comes equipped with a surge generator, TDR Pre-Location scope and a solar capable inverter charger. The LiFePo4 battery can be charged from mains as well as a solar panel where mains is not available. Total running time at full out- put is 3.5 hours.
Our MCLS (Mains Condition Lockout System) ensures proper and safe earthing connection. The MCLS system also ensures the quality of the mains power source.
Output Voltage :
4, 8, 16kV All Ranges 500 Joule (Ws)
MCLS :
(Mains Condition Lockout System)
Checks Polarity
Checks Mains Hi
Checks Mains Low
Checks Earthing Integrity
Pulse Rate :
Every 3-10 Seconds
Single Shot
DC Test :
16kV@200mA
Burning Function :
16kV@ 200mA Limited to short period only
Capacitor :
Steel Enclosed Oil Filled(Non PCB)
Porcelain Insulators
Enclosure :
308 Stainless Steel IP21
HV Transformer :
Dry Type Temperature Protected
4 Individual Secondary Coils
Test Method Options :
TDR and ICE
Dimensions :
580WX679DX1114mmH
Weight :
108kg
Test Environment :
Temperature Indoor and outdoor: 10oC to + 50oC.
Humidity: ≤ 85%
Supply Voltage :
230V 50/60Hz, 16A
Battery :
100Ah LiFePo4, 12.8V
Solar Panel Input :
Yes
Warranty :
1 Year
Standard Accessories :
High voltage test lead
Mains lead
Earth Lead
Optional Accessories :
GMA205 Ground Microphone
36V, 10A Solar Panel for MPPT Charger